Testing Yanmar CL Fuel Injection Pump
I. Pump Adjustment
- Preparation
- Mount pump on test stand.
- Install Yanmar rack indicator part number
158090-51500.
- Ensure the total rack travel is 11.5 to 12.5 mm and that the control
rack moves smoothly thru the full length of it's travel.
- Add 200 cc of engine oil to pump.
- Top Clearance Adjustment
- Remove delivery valve holder and delivery valve.
- After zeroing, install dial indicator, Yanmar special tool 158090-51300.
- Rotate camshaft to bring plunger to top dead center.
- Measure distance between top surface of barrel and top of plunger.
- If top clearance is not within specification, adjust to calibration
spec with shim.
- Retorque delivery valve holder to 25 - 29 ft/lb.
- IMPORTANT: Top clearance must always be above 0.3mm.
- Injection Timing Adjustment
- With throttle in wide open position, rotate pump by hand in
clockwise
rotation until injection begins on #1 cylinder.
- Check injection timing with flywheel scale. Re-check several times.
- Repeat steps #1 and #2 for each cylinder.
- Timing specifications are as follows:
| 3 Cylinder Pump | 4 Cylinder Pump |
| Injection Order |
1-2-3-1 |
1-3-4-2-1 |
| Injection Timing |
120° |
90° |
| Allowable Deviation |
±30' |
±30' |
- Readjust top clearance of cylinders not within allowable range.
| Shim Thickness |
Injection Timing Change |
| Change |
Cam Angle |
Crank Angle |
| 0.1 mm (0.0039 in |
0.5° |
1.0° |
- Testing Plunger Pressure
- Install plunger gauge, part number 121820-92540, to delivery valve holder.
- Operate pump at 200 RPM with the rack in shutoff position.
- Slowly move rack to fuel delivery position until pressure gauge
reaches
500 kg/cm2 (7110 psi).
- Immediately return rack to no fuel position.
- Check for external leaks or sudden pressure drop.
- If 500 kg/cm2 pressure can not be reached, replace plunger & barrel.
- Keep pressure guage installed for delivery valve test.
- Delivery Valve Leakage Test
- Operate pump at 200 RPM with the rack in shutoff position.
- Slowly move rack to fuel delivery position until pressure gauge
reaches
120 kg/cm2 (1706 psi).
- Measure time interval for pressure to drop from 100 kfg/cm2 to
90 kgf/cm2 (1422 - 1280 psi).
- If interval is less than 5 seconds, clean or replace delivery valve and
re-test.
- Injection Volume Adjustment
- Lock rack at rated position, using special bolt part number 158090-51010.
- Adjust pump at rated speed to rated RPM.
- Check delivery volume per calibration specifications.
- Correct delivery of each cylinder as follows:
- Lock rack in shutoff position.
- Loosen pinion locking screw.
- Rotate control sleeve (left decreases fuel, right increases fuel).
- Retest delivery to confirm adjustments. Readjust if necessary.
II. Governor Adjustment
- NOTE: If pump uses torque spring, destroke spring using special nut
part number 158090-51520.
- Operate pump at rated speed (WOT).
- Adjust rack to the rated position using fuel limit bolt and lock nut.
- Confirm that rated volume is within calibration specification.
- Readjust fuel limit bolt as necessary.
- High Idle Adjustment
- Operate pump at high idle speed (WOT).
- Adjust volume to calibration specification with the high idle bolt.
- Low Idle Adjustment
- Place throttle lever in idle position.
- Operate pump at low idle speed and check volume.
- Adjust delivery volume to calibration spcification with the low idle bolt.
- Cranking Speed Delivery
- Operate pump at start speed (WOT).
- Confirm delivery volume per calibration data.
- Torque Rise Adjustment
(Only for pumps equipped with torque or angleich springs)
- Torque Spring Models
- Remove special nut installed prior to fuel limit adjustment
- Operate pump at rated load speed with throttle in the wide open position.
- Slowly reduce pump speed to peak torque and confirm the rack moves
smoothly to peak torque position.
- Confirm the injection volume is within specification as per test plan.
- Angleich Spring Models
- Operate pump at peak torque speed (WOT).
- Remove rear lower governor case cover.
- Adjust delivery volume with angleich spring capsule.
- Retorque angleich spring capsule locknut.
- Operate pump at rated speed (WOT) and confirm rack is at rated
position
as per calibration specs.
- Fuel Shutoff
- Operate pump at rated speed with throttle in wide open position.
- Move fuel shutoff lever to shutoff position.
- Confirm that fuel delivery stops.